Fictional example

Sample test & tag report

This example shows how a report is laid out. The customer, site, equipment and readings are invented.

SAMPLE - NOT A TEST RECORD

This page is for illustration only and is not a record of any inspection or test.

Job summary

Job ID
SAMPLE-0001
Customer
Example Widgets Ltd (fictional)
Site
Level 1, 00 Example Street, Christchurch (fictional)
Visit date
2026-09-15
Agreed scope
Accessible plug-in office appliances and separately testable leads on Level 1. Comms cupboard equipment excluded from routine testing pending change approval.
Tester identifier
T-01
Instrument reference
INSTR-SAMPLE (fictional reference)
Report version
1.0

Result totals

3Completed/pass
1Completed/fail
1Visual inspection only
1Deferred
1Inaccessible
1Excluded
8Total assets listed

Asset results

Asset results, fictional
Asset IDDescriptionLocationMethodReadingsStatusNext testNotes
SAMPLE-A001Monitor 24 inchL1 desk 04Class I insulation and earth continuity0.08 ohm earth / >200 Mohm IR Completed/pass 2027-09
Office environment, agreed interval
-
SAMPLE-A002IEC power lead 2 mL1 desk 04Lead test0.06 ohm earth / >200 Mohm IR Completed/pass 2027-09
Office environment, agreed interval
-
SAMPLE-A003Power board 4-outletKitchenVisual inspection- Completed/fail -
Removed from use
Contact notified 10:42; item tagged out and handed to office manager.
SAMPLE-A004Network switch 24-portComms cupboard-- Deferred -
Requires approved change window
Supports shared services. Refer to IT lead for change approval.
SAMPLE-A005Multifunction printerCopy room-- Inaccessible -
Re-attempt next visit
Plug behind fixed cabinetry; access to be arranged.
SAMPLE-A006Desk fanL1 desk 11Visual inspection only- Visual inspection only -
Electrical test to be scheduled
Manufacturer guidance to be confirmed before test.
SAMPLE-A007Wall-mounted heater (hard-wired)Meeting room-- Excluded -
Outside service scope
Fixed wiring and hard-wired appliances are not covered.
SAMPLE-A008KettleKitchenClass I insulation and earth continuity0.05 ohm earth / >200 Mohm IR Completed/pass 2027-03
Kitchen use, agreed interval
-

Follow-up actions

  • SAMPLE-A003 (Completed/fail): Contact notified 10:42; item tagged out and handed to office manager. Follow-up owner: customer site contact.
  • SAMPLE-A004 (Deferred): Supports shared services. Refer to IT lead for change approval. Follow-up owner: customer site contact.
  • SAMPLE-A005 (Inaccessible): Plug behind fixed cabinetry; access to be arranged. Follow-up owner: customer site contact.
  • SAMPLE-A006 (Visual inspection only): Manufacturer guidance to be confirmed before test. Follow-up owner: customer site contact.

Limitations

Results record equipment condition at the time of inspection and testing only. This is not an electrical installation certificate and does not cover fixed wiring. Untested items are not given a pass result.